Commands
- chmf :
to change the current working main frame !
- cd :
go back to the main frame from looking at a specific slot!
- cd slot :
select which specific slot you wan to look at!
- clear :
clear the screen!
- direct mode :
this allows you to enter original MF commands direclty,if you want to
enter MF commands directly without going into the direct mode, you can
simply put a "/" in the front of the command.
- echo off :
no direct reply from MF is showing on STO
- echo on :
direct reply from MF will be showing on STO
- empty slots :
list all the empty slots in the current mainframe.
- empty slots (m1)-(m2) :
list all the empty slots in mainframe (m1) to mainframe (m2)
- hvoff :
turn off the high voltage
- hvoff all :
turn off the high voltage for all the mainframes
- hvoff (m1)-(m2) :
turn off the high voltage from mainframe (m1) to mainframe (m2)
- hvon :
turn on the high voltage
- hvon all:
turn on the high voltage for all the mainframes
- hvon (m1)-(m2):
turn on the high voltage from mainframe (m1) to mainframe (m2)
- hvstatus :
return the high voltage status of the current main frame
- list :
if a specific slot is chosen, then list all channles information in
the slot,else list all the slots information in the current main
frame.
- list mainframes :
list all the mainframes on the network and its high voltage
status.
- list modules :
lists all the existing slots in the main frame with their
informations
- list slot (slot number) :
lists all channles information of the specified slot
- list slot (s1)-(s2) (option):
lists all channels information of the slots range from(s1) to
(s2). (option) is the submodule number of the slots.
- normal mode:
back to normal mode from direct mode
- set slot (s1)-(s2) (submodule number) (property) (value):
set the property of the submodules in the slots from s1 to s2 to
(value)
- set (submodule number) (channel number) (property)
(value):
set the property of the channel in the specified submodule to
value, assuming that the user is looking at a specific slot.
- set (submodule number) (c1)-(c2) (property) (value):
set the property of a range of channels from c1 to c2 in the
specified submodule to value. Assuming that the user is looking at a
specific slot
- quit :
quit the program !