Phenix Ancillary Temperature Measurement Requirements
date: 10/11/94
EMCAL requirements
accuracy: .1 degree C
range: 20 - 60 degree C
sensor type: RTD
operational requirements
Alarm operators on overheading for tube sections of Pb Sc and crystals underheating on the crystal insides and on the existance of a temperature gradient between sensors display
units:
Celcius
physical location
The temperature sensors will be located on supermodules.
Quantity
crystals
- 64: 4 heater foils for each of 16 supermodules
- 128: 8 readout sensors (RTD) for each of 16 supermodules Pb
PbGl
Unknown at this time.
PbSi
- no heaters
- 216 temperature sensors (2 per supermodule; 108 supermodules)
- total: 344
******************************************************************
BB requirements:
sensor type:
Unknown at this time.
MVD
requirements:
sensor type:
Unknown at this time.
RICH
requirements:
sensor type:
Unknown at this time.
TOF
requirements:
sensor type:
Unknown at this time.
TRACKING
requirements:
sensor type:
Unknown at this time.
MUON ID
requirements:
sensor type:
PHENIX COOLING
requirements:
sensor type:
Unknown at this time.
monitoring functions:
unknown
person responsible: unknown
total phenix requirements:
- monitoring: 474 channels
- control: unknown
-
Phenix Home Page -
Online
Computing Group -