PPT Slide
- Read in DCM packets and put data into “Raw Data Format”; sort by arm, station, octant, plane, strip/wire so data is more easily accessed
- Apply calibrations - constant gain now, but class defined which should conform to database access easily (Mark P. and R.B.)
- Find cathode clusters (contiguous set of cathodes above threshold) and store in cluster table
- Fit clusters based on cluster size, shape, C2 of fit.
- Pattern recognition and track reconstruction
- Event display and NTUPLE/histogram examination