LVPS Crates-to-MuID Panels
Maximum supply current determines sizing of conductors to RIS 13030 power distribution box.
- +/- 12V: Imax = 100W/12V*1.25 = 10.4A.
Power brought from supply to distribution boxes (near MUID panels).
- Lug connections at supply.
- Alpha # 5630B1801 (18 AWG, passes UL vertical flame tray test, 1000 feet total).
- Amphenol connector (97-3102A-A-1 4P, rated UL 94V-0) at distribution box input.
Power brought to internal distribution board.
- Alpha #83029 (18 AWG, passes VW-1 vertical flame test).
- Molex connector (WM2113/4622, rated UL 94V-0).