==================================================== Important EPICS High Voltage Record Data Base Fields ==================================================== The fields are addressed by appending extensions to the channel names. Fields as CEI are the INPUT fields to EPICS and have to be addressed in order to retrieve the current settings as stored in the database. The same fields but ending on "O" (e.g. CEO) are used to output values to the data base and to modify the current settings. 1471N modules: ============== HV_DC_W_S_KS00_X1__C.CEI channel enable 1=en. 0=dis. HV_DC_W_S_KS00_X1__C.CZI current dead zone (uA) HV_DC_W_S_KS00_X1__C.TCI trip current (uA) HV_DC_W_S_KS00_X1__C.DVI demand voltage (V) HV_DC_W_S_KS00_X1__C.VZI voltage dead zone (V) HV_DC_W_S_KS00_X1__C.RUI ramp up rate (V/s) HV_DC_W_S_KS00_X1__C.RDI ramp down rate (V/s) HV_DC_W_S_KS00_X1__C.PTCI peak trip current (uA) HV_DC_W_S_KS00_X1__C.RTI ramp trip enable 1=en. 0=dis. 1469N modules: ============== a/ normal channels HV_DC_W_S_KS00_X1__P.CEI channel enable 1=en. 0=dis. HV_DC_W_S_KS00_X1__P.CZI current dead zone (uA) HV_DC_W_S_KS00_X1__P.TCII trip current (uA) b/ bulk supply channels HV_DC_W_S_KS00-03_PBS.CEI channel enable 1=en. 0=dis. HV_DC_W_S_KS00-03_PBS.CZI current dead zone (uA) HV_DC_W_S_KS00-03_PBS.TCI trip current (uA) HV_DC_W_S_KS00-03_PBS.DVI demand voltage (V) HV_DC_W_S_KS00-03_PBS.VZI voltage dead zone (V) HV_DC_W_S_KS00-03_PBS.RUI ramp up rate (V/s) HV_DC_W_S_KS00-03_PBS.RDI ramp down rate (V/s)