power distribution and grounding
power distribution and grounding
- bias HV distributed via half sector detector anode planes
- low voltage power distributed via FEM board for each half sector
- separate digital and analog ground planes for FEM boards
- LDO series regulators used on FEM to isolate FEM’s power from common voltage buses in detector
- 5 sets of 3 LDO series regulators regulate DMU +5, TGLDx +5 digital & TGLDx +5 analog for each row of 9 ROCs
- ROC power supplies are multiply bypassed
- local reference & bias voltages for TGLDx chips are multiply bypassed
- local pixel HV bias bypass caps are referenced back to the analog Vdd of the ROC